SAME DAY SHIPPING M-F FOR IN STOCK ITEMS PLACED BY 12PM CST | EXPEDITED SHIPPING OPTIONS AVAILABLE AT CHECKOUT
Your Cart is Empty
SAME DAY SHIPPING M-F FOR IN STOCK ITEMS PLACED BY 12PM CST | EXPEDITED SHIPPING OPTIONS AVAILABLE AT CHECKOUT
Your Cart is Empty
Arc Stud Welders with traditional transformers require more power than you think because the draw time for the generator is less than one second so the generator has to be able to supply the power at idle speed. The stud welder has too fast of a current draw for the generator to be able to react.
GENERATOR SIZING RECOMMENDATION
|
||
STUD DIAMETER | TRADITIONAL TRANSFORMER SYSTEM MINIMUM RECOMMENDED | INVERTER SYSTEM MINIMUM RECOMMENDED |
3/8" | 40kw |
20kw |
1/2" | 70kw | 35kw |
5/8" | 80kw |
40kw |
3/4" | 200kw |
100kw |
7/8" |
250kw |