    Arc Stud Welders with traditional transformers require more power than you think because the draw time for the generator is less than one second so the generator has to be able to supply the power at idle speed. The stud welder has too fast of a current draw for the generator to be able to react.


    GENERATOR SIZING RECOMMENDATION
    STUD DIAMETER TRADITIONAL TRANSFORMER SYSTEM MINIMUM RECOMMENDED INVERTER SYSTEM MINIMUM RECOMMENDED
    3/8" 40kw
    20kw
    1/2" 70kw 35kw
    5/8" 80kw
    40kw
    3/4" 200kw
    100kw
    7/8"

    250kw